Application : thermocouple Sensor , temperature measurement
Item : 0.04mm To 0.5mm S Type Thermocouple Wire For High Temperature Measuring
0.04mm To 0.5mm S Type Thermocouple Wire For High Temperature sensor
Introduction:
Type R, S, and B thermocouples are "Noble Metal" thermocouples, which are used in high temperature applications.
Type S thermocouples are characterized by a high degree of chemical inertness and stability at high temperatures. Often used as a standard for calibration of base metal thermocouples
Platinum rhodium thermocouple(S/B/R TYPE)
Platinum Rhodium Assembling Type Thermocouple is widely used in production places with high temperature. It is mainly used to measure temperature in glass and ceramic industry and industrial salting
0.04mm To 0.5mm S Type Thermocouple Wire For High Temperature sensor
Characteristics:
The thermocouple wires have excellent performance and are extensively used in the temperature measurement and control in different fields, such as metallurgy, chemical industry, petroleum industry, machinery-electric industry, energy industry, agriculture and military industry.
Tankii products conform to the standards of IEC584 -1and IEC-2.
Thermocouple type and index | Measurement Range ℃ | |
Type | Index | |
| B | 600~1700 |
| R | 0~1600 |
| S | 0~1600 |
| K | -200~1300 |
| E | -200~900 |
| J | -40~750 |
| T | -200~350 |
| N | -200~1300 |
The allowable grade and Tolerance are obtained at 0℃
Thermocouple | Grade | Temperature range | Allowable Tolerance /℃ |
Type B | Ⅱ | 600~1700 | ±0.25% t |
Ⅲ | 600~800 | ±4 | |
800~1700 | ±0.5%t | ||
Type R(S) | Ⅰ | 0~1100 | ±1 |
1100~1600 | ±[1+(t-1100) ×0.3%] | ||
Ⅱ | 0~600 | ±1.5 | |
600~1600 | ±0.25% t | ||
Type K and Type N | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type E | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type J | Ⅰ | -40~750 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~750 | ±2.5℃ or ±0.75%t | |
Type T | Ⅰ | -40~350 | ±0.5℃ or ±0.4%t |
Ⅱ | -40~350 | ±1.0℃ or ±0.75%t | |
Ⅲ | -200~40 | ±1.0℃ or ±1.5%t |
Shanghai tankii, specializing in producing thermocouple wire, thermocouple cable, thermocouple MI cable.
A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, a thermal “electromotive” force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions.